S-502 CLOSED SWAGE SOCKET

  • Forged from special bar quality carbon steel, suitable for cold forming.
  • Hardness controlled by spheroidize annealing.
  • Swage Socket terminations have an efficiency rating of 100% based on the catalog strength of wire rope.
  • Stamp for identification after swaging without concern for fractures (as per directions in National Swaging Brochure).

NOTE:  S-502 Swage Sockets are recommended for use with 6 x 19 or 6 x 37, IPS or XIP (EIP), XXIP (EEIP), RRL, FC or IWRC wire rope.

Before using any National Swage fitting with any other type lay, construction or grade of wire rope, it is recommended that the termination be destructive tested and documented to prove the adequacy of the assembly to be manufactured.

In accordance with ANSI B30.9, all slings terminated with swage sockets shall be proof loaded.*

 

 

Swage sockets incorporate a reduced machined area of the shank which is equivalent to the proper after Swage dimension.  Before swaging, this provides for an obvious visual difference in the shank diameter.  After swaging, a uniform shank diameter is created allowing for a QUIC CHECK® and permanent visual inspection opportunity.

Designed to quickly determine whether the socket has been through the swaging operation and assist in field inspections, it does not eliminate the need to perform standard production inspections which include gauging for the proper after swage dimensions or proof loading.

U.S. Patent 5,152,630 and foreign equivalents.

 

S-502 Closed Socket Specifications Press/ Die Data
Stock No.
Rope Size
(in.)
Weight Each
(lbs.)
Before Swage Dimensions Max. After Swage Dim.
(in.)
Die
Description
Stock No. Side Load
A B C D E F H L 500 Ton
1000 Ton
1500 Ton
5x7
1500 Ton
3000 Ton
6x12
1500 Ton
6x12
3000 Ton
6x12
1039325 1/4 .33 4.31 .50 1.38 .75 .27 2.12 .50 3.50 .46 1/4
SOCKET
1192845
1039343 5/16 .75 5.44 .77 1.62 .88 .34 3.19 .67 4.50 .71 5/16 - 3/8
SOCKET
1192863
1039361 3/8 .72 5.44 .77 1.62 .88 .41 3.19 .67 4.50 .71 5/16 - 3/8
SOCKET
1192863
1039389 7/16 1.42 6.91 .98 2.00 1.06 .48 4.25 .86 5.75 .91 7/16 - 1/2
SOCKET
1192881
1039405 1/2 1.42 6.91 .98 2.00 1.06 .55 4.25 .86 5.75 .91 7/16 - 1/2
SOCKET
1192881
1039423 9/16 2.92 8.66 1.25 2.38 1.25 .61 5.31 1.13 7.25 1.16 9/16 - 5/8
SOCKET
1192907
1039441 5/8 2.85 8.66 1.25 2.38 1.25 .67 5.31 1.13 7.25 1.16 9/16 - 5/8
SOCKET
1192907
1039469 3/4 5.00 10.28 1.55 2.88 1.44 .80 6.38 1.31 8.63 1.42 3/4
SOCKET
1192925
1039487 7/8 6.80 11.94 1.70 3.12 1.69 .94 7.44 1.50 10.13 1.55 7/8
SOCKET
1192949
1039502 1 10.40 13.56 1.98 3.63 2.06 1.06 8.50 1.75 11.50 1.80 1  
SOCKET
1192961
1039520 1-1/8 14.82 15.03 2.25 4.00 2.31 1.19 9.56 2.00 12.75 2.05 1-1/8
SOCKET
1192989
1039548 1-1/4 21.57 16.94 2.53 4.50 2.56 1.33 10.63 2.25 14.38 2.30 1-1/4
SOCKET
1193005
1039566 1-3/8 28.54 18.63 2.80 5.00 2.56 1.45 11.69 2.25 15.75 2.56 1-3/8
SOCKET
1193023
1039584 1-1/2 38.06 20.12 3.08 5.50 2.81 1.58 12.75 2.50 17.00 2.81 1-1/2
SOCKET
1193041 1191267 1193355 1195192
1039600 1-3/4 51.00 23.56 3.39 6.25 3.56 1.86 14.88 3.00 20.00 3.06 1-3/4
SOCKET
1193069 1191276 1195367 1195209
1042589 2 89.25 27.62 3.94 7.25 3.81 2.11 17.00 3.25 23.00 3.56 2 SOCKET 1193087 1191294 1195379 1195218

* Maximum Proof Load shall not exceed 50% of XXIP rope catalog breaking strength.