[PRODUCTS PAGE, HOME]
Catalog provided courtesy of The Crosby Group, Inc.
Previous Page National Swage Fittings Next Page
Page 040

                                                  COLD TUFF® BUTTON

 
S-409
  • Special processed, low carbon steel.
  • “Cold Tuff ® ” for better swageability.
  • Swage Button terminations have an efficiency rating of 98% based on the catalog strength of wire rope.
  • Stamp for identification after swaging without concern for fractures (as per directions in National Swaging Brochure).
NOTE:  S-409 Buttons are recommended for use with 6 x 19 or 6 x 37, IPS or XIP (EIP), RRL, FC or IWRC wire rope. Before using any National Swage fitting with any other type lay, construction or grade of wire rope, it is recommended that the termination be destructive tested and documented to prove the adequacy of the assembly to be manufactured.

S-409 Steel Swage Button Specifications Press/ Die Data
Size No. Stock No. Rope Size
(in.)
Weight
Per
100 Pcs. (lbs.)
Before Swage Dimensions After Swage
Dimensions
Die Desc. Stock No.
500 Tons
1000 Tons
1500 Tons
5 x 7
A B C D
Maximum After Swage
Dimensions
E
Length
1 SB 1040171 1/8 2 .44 .50 .14 .40 .61 1/8 - 1/4 Button 1191621
3 SB 1040215 3/16 4 .56 .70    .20 .52 .84 1/4 1st Stage 1197528
5 SB 1040251 1/4 8 .63 1.06 .30 .58 1.20 1/8 - 1/4 Button 1191621
7 SB 1040297 5/16 16 .88 1.13 .36 .77 1.33 3/8 1st Stage 1192364
8 SB 1040313 3/8 15 .88 1.48 .42 .77 1.69 3/8 1st stage 1192364
9 SB 1040331 7/16 30 1.13 1.63 .48 1.03 1.94 1/2 1st Stage 1192408
10 SB 1040359 1/2 50 1.31 1.89 .55 1.16 2.17 5/8 socket 1192907
11 SB 1040377 9/16 70 1.44 2.02 .61 1.29 2.41 9/16 -5/8 Button 1191665
12 SB 1040395 5/8 100 1.56 2.42 .67 1.42 2.89 9/16 -5/8 Button 1191665
13 SB 1040411 3/4 131 1.69 2.73 .79 1.55 3.25 3/4 1st Stage 1192462
14 SB 1040439 7/8 220 2.00 3.27 .94 1.80 3.86 7/8 1st Stage 1192480
15 SB 1040457 1 310 2.25 3.67 1.06 2.05 4.36 1 1st Stage 1192505
16 SB 1040475 1-1/8 450 2.56 4.05 1.19 2.30 4.81 1-1/8 1st Stage 1192523
17 SB 1040493 1-1/4 650 2.81 4.58 1.33 2.56 5.42 1-3/8 Socket 1193023

NOTE:  Length is measured from outside end of termination.