[PRODUCTS PAGE, HOME]
Catalog provided courtesy of The Crosby Group, Inc.
Previous Page Crosby® Shackles Next Page
Page 068
Angle loads must
be applied in the
plane of the bow.

Shackle Inspection

Side Loading Reduction Chart
 For Screw Pin and Bolt Type Shackles Only †
 Angle of Side Load
 from Vertical In-Line of shackle
 Adjusted Working Load Limit
 0° In-Line *  100% of Rated Working Load Limit
 45° from In-Line *  70% of Rated Working Load Limit
 90° from In-Line *  50% of Rated Working Load Limit

*  In-Line load is applied perpendicular to pin.
† DO NOT SIDE LOAD ROUND PIN SHACKLES


 

Never Exceed 120° included angle.
Use Bolt Type and Screw Pin Shackles ONLY.

Shackles symmetrically loaded with two leg slings having a maximum included angle of 120° can be utilized to full Working Load Limit.

Previous Page Copyright © 2003  The Crosby Group, Inc.  All rights reserved Next Page